Logical "AND" of Opto Output and Relay Driver
The Opto Inputs and Outputs are fully isolated.<br /><br />
 
==Logical "AND" of Opto Output and Relay Driver==
Both the Relay Driver and Opto Output need to be active to enable the Solid State Relay (SSR).  Such a circuit can be used to assure a SSR remains off until after KFLOP Boots and SWE Relay Driver output goes active and KFLOP is initialized and the Opto Output is activated.
 
Note positions of the SSR and Opto Output may be reversed if desired.  But because relay driver outputs are internally grounded it must be at the bottom.
 
 
[[File:RelayDriverAndOptoInSeries.png|none|link=|329x469px]]